    Key specifications:

    Specification Value
    Model RXQ10BYM
    Refrigerant type R410a – Environmentally friendly
    Mode Cooling only
    Cooling capacity 95,500 Btu/h (~28.0 kW)
    Power consumption 6.41 kW
    Dimensions (Height x Width x Depth) 1,660 x 930 x 765 mm
    Weight 210 kg
    Share:
    Contact us for advice
    Get a quote: 0909326888
    Out of stock

    Daikin VRV A cooling-only outdoor unit, R410a refrigerant – Model RXQ10BYM | Powerful performance, energy efficient

    Daikin VRV A cooling-only outdoor unit, R410a refrigerant – Model RXQ10BYM | Powerful performance, energy efficient

    Introducing the VRV A RXQ10BYM outdoor unit

    The outdoor unit VRV A cooling-only, model RXQ10BYM is a premium product in Daikin's central air conditioning system range, known for powerful cooling, reliable operation and optimal energy efficiency. With a cooling capacity of up to 95,500 Btu/h (~28.0 kW), this unit is an ideal choice for commercial projects, office buildings, hotels or large shopping centers.


    Key specifications

    Specification Value
    Model RXQ10BYM
    Refrigerant type R410a – Environmentally friendly
    Mode Cooling only
    Cooling capacity 95,500 Btu/h (~28.0 kW)
    Power consumption 6.41 kW
    Dimensions (Height x Width x Depth) 1,660 x 930 x 765 mm
    Weight 210 kg

    Key advantages of the RXQ10BYM outdoor unit

    • ✅ Energy saving: The outdoor unit uses advanced inverter technology to effectively reduce power consumption.

    • ✅ Quiet and stable operation: With its optimized design and high-quality materials, the product minimizes operating noise.

    • ✅ Compact design, easy installation: Its practical dimensions provide flexibility when choosing an installation space.

    • ✅ Uses environmentally friendly R410a refrigerant: The refrigerant does not harm the ozone layer and meets modern environmental standards.


    Practical applications

    The outdoor unit Daikin VRV RXQ10BYM is suitable for a range of medium- and large-scale projects, such as:

    • Offices and high-rise buildings

    • Hotels, resorts and shopping centers

    • Hospitals, schools and factories


    Why choose the VRV A RXQ10BYM outdoor unit?

    • ? High reliability from the Daikin brand

    • ? A smart, expandable central air conditioning system

    • ? Long-term technical support and maintenance


    Contact us now to get the best quote

    If you are looking for an efficient, economical and sustainable cooling solution, don't overlook the VRV A RXQ10BYM outdoor unit. Contact us to get the best quote, technical support and advice on designing a system that meets your needs.

    🔧 1. Preparation before installation

    ✅ Required tools and equipment:

    • Pressure gauge, clamp meter

    • Vacuum pump, copper pipe welding machine

    • Screw-tightening tools, torque wrench, adjustable wrench

    • Copper pipe meeting specifications (at least Type L)

    • Compliant electrical wiring (power cable, control cable)

    • Support base or mounting frame (if installing on a roof)

    ✅ Check that the installation location is suitable:

    • A level, sturdy surface that can support at least 300kg (the unit weighs 210kg)

    • Clearance requirements:

      • At least 300mm at the sides

      • At least 1,000mm at the front

      • Avoid direct sunlight and locations exposed to strong winds


    🧱 2. Securing the outdoor unit

    ✅ Secure installation:

    • Place the outdoor unit on a mounting frame or concrete base with anti-vibration rubber pads.

    • Secure it firmly using expansion bolts or dedicated screws.

    • Ensure the unit is perfectly level to prevent vibration and compressor damage.


    🌀 3. Connecting the copper pipes

    ✅ Copper pipe requirements:

    • Use the sizes specified by Daikin (refer to the technical manual for model RXQ10BYM)

    • Braze with nitrogen to prevent pipe oxidation

    • Insulate all refrigerant pipes (liquid and gas pipes)

    ✅ Pipe length and height difference:

    • Maximum total pipe length: approximately 165m (follow the technical catalogue)

    • Maximum height difference: 50m

    • Install an oil separator if the height difference exceeds 40m


    ⚡ 4. Electrical connection

    ✅ Power supply:

    • 3-phase 380V - 50Hz power

    • Adequately rated power cable (minimum 4-6 mm²), with a grounding wire

    • A separate circuit breaker or CB for each outdoor unit

    ✅ Connect according to the wiring diagram:

    • Follow the manufacturer's wiring diagram

    • Use dedicated, shielded control cable


    💨 5. Evacuation and refrigerant charging

    ✅ Evacuate the entire system:

    • Connect a gauge and vacuum pump to the service valve

    • Evacuate for at least 30 minutes or until the pressure is < -760mmHg

    • Check for leaks using soapy water spray or a refrigerant leak detector

    ✅ Charging with R410a refrigerant (if additional charge is required):

    • Calculate the refrigerant quantity based on the actual pipe length

    • Use the correct R410a refrigerant, charge in liquid form, do not charge in vapor form

    • Weigh the refrigerant using an electronic scale


    🧪 6. Test run and inspection

    • Turn on the power CB and check that the voltage is stable

    • Start the system using the central controller

    • Check the current, refrigerant pressure, noise and vibration

    • Ensure that no errors are displayed and that the unit operates stably


    📋 7. Handover and operating instructions

    • Provide the customer with technical guidance on operation and basic maintenance

    • Record the installation specifications: pipe length, refrigerant charge, electrical specifications

    • Provide the warranty certificate, installation log and technical documents


    ⚠️ Important notes

    • Installation must be carried out by a Daikin-certified or authorized technical contractor

    • Installation errors may result in loss of warranty, reduced performance or equipment damage


    Would you like me to create a professional installation guide PDF or with illustrative diagrams of the piping, electrical connections and installation location?

    Technical specifications

    Customer reviews

    5.0
    5
    0%
    4
    0%
    3
    0%
    2
    0%
    1
    0%

    Share your product feedback

    Ratings and reviews

      Sender information

      To submit a comment, please provide your contact information
      Update
      • There are no products in the cart yet