Key technical specifications:
-
Model: RXQ8BYM
-
Type: VRV A outdoor unit – cooling only
-
Refrigerant: R410a – safe and environmentally friendly
-
Cooling capacity: 76,400 Btu/h (~22.4 kW)
-
Power consumption: 5.00 kW
-
Dimensions (Height x Width x Depth): 1,660 x 930 x 765 mm
-
Weight: 206 kg
VRV A Cooling-Only Outdoor Unit with R410a Refrigerant – Model: RXQ8BYM | Capacity 76,400Btu/h
VRV A cooling-only outdoor unit Model RXQ8BYM is the optimal choice for commercial properties and modern office buildings. The product uses environmentally friendly R410a refrigerant, delivering high performance and significant energy savings. With a capacity of up to 76,400Btu/h (~22.4kW), this unit effectively meets the cooling needs of large spaces with high operational stability.
Key technical specifications:
-
Model: RXQ8BYM
-
Type: VRV A outdoor unit – cooling only
-
Refrigerant: R410a – safe and environmentally friendly
-
Cooling capacity: 76,400 Btu/h (~22.4 kW)
-
Power consumption: 5.00 kW
-
Dimensions (Height x Width x Depth): 1,660 x 930 x 765 mm
-
Weight: 206 kg
Outstanding advantages of the VRV A RXQ8BYM outdoor unit:
-
High performance: With a capacity of 22.4kW, the product is ideal for medium- and large-scale central air conditioning systems.
-
Energy savings: Inverter technology combined with R410a refrigerant helps optimise performance and reduce operating costs.
-
Compact, robust design: Easy to install and maintain thanks to its practical dimensions and durable construction.
-
Quiet operation: Minimises noise, making it suitable for installation in urban environments, hotels and offices.
Applications:
The VRV A RXQ8BYM outdoor unit is widely used in:
-
Office buildings
-
Hotels, resorts
-
Shopping centres
-
Large-scale factories and cold storage facilities
Why choose the Daikin VRV RXQ8BYM outdoor unit?
Daikin is a leading Japanese brand in air conditioning. The RXQ8BYM incorporates advanced technology, high durability and outstanding operational stability – the perfect solution for professional central air conditioning systems.
Contact us now for expert advice and the best quotation for the VRV A Model RXQ8BYM outdoor unit!
Guide to Correct Technical Installation of the VRV A RXQ8BYM Outdoor Unit
Correct installation not only helps the VRV RXQ8BYM outdoor unit operate reliably but also extends equipment life and ensures optimal cooling performance. Below are the essential requirements and considerations during installation:
1. Ideal installation location
-
Install in a well-ventilated location, away from direct sunlight and wind-driven rain.
-
Do not install in locations with exhaust gases or corrosive vapours, near chemicals or in polluted environments.
-
Maintain minimum clearances from walls:
-
Rear: ≥ 300 mm
-
Front (airflow): ≥ 1,000 mm
-
Both sides: ≥ 300 mm on each side
-
-
Ensure a firm, level surface, with no vibration or movement during operation.
2. Foundation requirements
-
The foundation must have adequate load-bearing capacity to support the weight of 206kg.
-
Installation on a concrete plinth or stainless steel support frame with anti-vibration rubber pads is recommended.
-
The tilt must not exceed 5° to prevent compressor oil leakage.
3. Refrigerant and condensate piping
-
Use standard copper piping for the R410a refrigerant system, with full insulation.
-
Piping length and elevation difference must comply with the manufacturer's instructions (maximum: 165m in length, 50m elevation difference between the outdoor and indoor units).
-
Design the condensate drain line with a continuous downward slope and a water trap if necessary.
4. Electrical connections
-
Power supply: 3 pha – 380V – 50Hz
-
Connect according to the wiring diagram, using Dedicated protective circuit breaker, grounding in accordance with applicable standards.
-
Do not share the power supply with other high-load equipment.
5. Inspection and operation
-
Check refrigerant pressure, and pipework leak-tightness before adding refrigerant.
-
Check the fan rotation direction and starting current, and test-run the entire system.
-
Ensure a no leaks, noise within permissible limits and a stable cooling temperature.
Important installation notes:
✅ Installation must be performed by technicians with Daikin VRV certification
✅ Do not modify components, refrigerant piping or connecting wiring without authorization
✅ Perform periodic maintenance every 3–6 months to ensure operating efficiency
Would you like me to include an installation schematic drawing or installation checklist to print out for practical use?
Technical specifications
Customer reviews
Share your product review
Ratings and reviewsRelated Products
RXQ18BYM
RXQ16BYM
RXQ14BYM
RXQ12BYM
RXQ10BYM
Daikin VRV A Max 60HP RXQ60AMYMW Outdoor Unit - HRT
DAIKIN VRV A Max 58HP RXQ58AMYMW Outdoor Unit - HRT
DAIKIN VRV A Max 56HP RXQ56AMYMW Outdoor Unit - HRT
Sender information
- There are no products in your shopping cart


